IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

According to Decree 280-2024 published on February 28, 2024, in the Gazette officielle du Québec, the amendment to the Appendix 1 of the Regulation respecting occupational health and safety (RSST, RLRQ, c. S-2.1, r. 13) will come into force on March 14, 2024. These regulatory changes have not yet been incorporated into the current Substance Data Sheets of the Sampling Guide for Air Contaminants in the Workplace. An update is currently underway and will be available as soon as possible. Consequently, the information contained in the data sheets of substances modified or added in Decree 280-2024 is partially inaccurate or incomplete. Please consult our infoLABO (in French only) for more details. Please contact our client service: [email protected] for further information.

Isobutyl alcohol  

French name in the regulation: Alcool isobutylique
CAS : 78-83-1

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 50 152 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1B : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Isobutyl alcohol

Analysis:

Alcool isobutylique

Method: IRSST - 278-1
Sampling device:
Sampling media required:
#IRSSTDescription
2120 Activated charcoal tube 100/50 mg

Parameters:
Flow rate: Max: 0.2 L/min
TWA sampling volume: 10 L
STEL sampling volume: -
Principle: Gas chromatography with flame ionization detection (GC-FID)
Precision (%): 6,4
Minimum reported value: 75 µg
Remarks: The analysis can be done by gas chromatography coupled with mass spectrometry (GC-MS, IRSST method #369); in this case the analytical uncertainty (CVa) is 7.6%.
IRSST. "Analyse de l'alcool isobutylique dans l'air". Méthode 278-1. Non publiée.

Isobutyl alcohol

Method: IRSST - 415
Sampling device:
Sampling media required:
#IRSSTDescription
2197 Anasorb 747 tubes (2) 400/200 mg in series

Parameters:
Flow rate: 0.05 L/min
TWA sampling volume: 12 L
STEL sampling volume: -
Remarks: At the end of sampling, the front tube must be separated from the back tube to avoid migration. Reseal each end of the tubes. Additional information is also available in french in "consigne d'utilisation I-MAT-039". Isobutyl alcohol must be sampled specifically because of the sampling device used.
Principle: Gas chromatography with flame ionization detection (GC-FID)
Precision (%): 0,5
Minimum reported value: 30 µg
Remarks: However, simultaneous sampling and analysis of Methyl alcohol, Ethyl alcohol, sec-Butyl alcohol, n-propyl alcohol, Isopropyl alcohol and n-Butyl alcohol is possible.
IRSST. Détermination des alcools prélevés sur tubes de charbon activé synthétique dans l'air (non publié)

Isobutyl alcohol

Method: IRSST - 416
Sampling device:
Sampling media required:
#IRSSTDescription
2696 566AT passive dosimeter

Parameters:
Flow rate: 0,0107 L/min
TWA sampling volume: -
STEL sampling volume: -
Remarks: For the monitors, the flow must be considered as being a sampling rate.
Principle: Gas chromatography with flame ionization detection (GC-FID)
Precision (%): 2,7
Minimum reported value: 8 µg
IRSST. "Dosage des composés organiques volatils dans l'air par dosimétrie passive". Méthode 416. Non publiée.