According to Decree 280-2024 published on February 28, 2024, in the Gazette officielle du Québec, the amendment to the Appendix 1 of the Regulation respecting occupational health and safety (RSST, RLRQ, c. S-2.1, r. 13) will come into force on March 14, 2024. These regulatory changes have not yet been incorporated into the current Substance Data Sheets of the Sampling Guide for Air Contaminants in the Workplace. An update is currently underway and will be available as soon as possible. Consequently, the information contained in the data sheets of substances modified or added in Decree 280-2024 is partially inaccurate or incomplete. Please consult our infoLABO (in French only) for more details. Please contact our client service: [email protected] for further information.

Acrolein  

French name in the regulation: Acroléine
CAS : 107-02-8

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 0,1 0,23 - -
STEV 0,3 0,69 - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1B : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Acrolein

Analysis:

Acroléine

Method: IRSST - 385
Sampling device:
Sampling media required:
#IRSSTDescription
2186 Orbo 23 tube 120/60 mg

Parameters:
Flow rate: 0,1 L/min
TWA sampling volume: 10 L
STEL sampling volume: -
Remarks: Before and after sampling, the tubes must be kept in the freezer.
Principle: Gas chromatography with mass spectrometry (GC-MS)
Precision (%): 9,9
Minimum reported value: 0,04 µg
Remarks: Eleven aldehydes are determined simultaneously: acetaldehyde, isobutyraldehyde, isovaleraldehyde, propionaldehyde, butyraldehyde, furfural, heptanal, hexanal, valeraldehyde, acrolein and formaldehyde. This method must not be used for the specific evaluation of formaldehyde; the methods to be used in this case are 295-1 and 357-1.
Dépistage des aldéhydes dans l'air par GC-MS. Méthode 385. Non publiée.

Acroléine

Method: IRSST - 385
Sampling device:
Sampling media required:
#IRSSTDescription
2188 XAD-2 120/60 mg impregnated with HMP

Parameters:
Flow rate: 0,1 L/min
TWA sampling volume: 10 L
STEL sampling volume: -
Remarks: Before and after sampling, the tubes must be kept in the freezer.
Principle: Gas chromatography with mass spectrometry (GC-MS)
Precision (%): 9,9
Minimum reported value: 0,04 µg
Remarks: Eleven aldehydes are determined simultaneously: acetaldehyde, isobutyraldehyde, isovaleraldehyde, propionaldehyde, butyraldehyde, furfural, heptanal, hexanal, valeraldehyde, acrolein and formaldehyde. This method must not be used for the specific evaluation of formaldehyde; the methods to be used in this case are 295-1 and 357-1.
Dépistage des aldéhydes dans l'air par GC-MS. Méthode 385. Non publiée.