According to Decree 280-2024 published on February 28, 2024, in the Gazette officielle du Québec, the amendment to the Appendix 1 of the Regulation respecting occupational health and safety (RSST, RLRQ, c. S-2.1, r. 13) will come into force on March 14, 2024. These regulatory changes have not yet been incorporated into the current Substance Data Sheets of the Sampling Guide for Air Contaminants in the Workplace. An update is currently underway and will be available as soon as possible. Consequently, the information contained in the data sheets of substances modified or added in Decree 280-2024 is partially inaccurate or incomplete. Please consult our infoLABO (in French only) for more details. Please contact our client service: [email protected] for further information.

2-Aminoethanol  

French name in the regulation: Amino-2 éthanol
CAS : 141-43-5
Synonyms: Éthanolamine

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 3 7,5 - -
STEV 6 15 - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: 2-Aminoethanol

Analysis:

Amino-2 éthanol

Method: IRSST - 303
Sampling device:
Sampling media required:
#IRSSTDescription
2170 XAD-2 tube 80/40 mg impregnated NIT

Parameters:
Flow rate: 0,2 L/min
TWA sampling volume: 4 L
STEL sampling volume: -
Principle: High performance liquid chromatography with UV detection (HPLC-UV)
Precision (%): 0,9
Minimum reported value: 0,3 µg
IRSST. "Analyse de l'amino-2 éthanol". Méthode 303. Non publiée.

Éthanolamine

Method: IRSST - 363
Sampling device:
Sampling media required:
#IRSSTDescription
955 FV filter impregnated with sulfuric acid

Parameters:
Flow rate: 1 L/min
TWA sampling volume: 15 L
STEL sampling volume: -
Remarks: The sample is stable for 2 weeks at 4°C.
Principle: High performance liquid chromatography with mass spectrometry (HPLC-MS)
Precision (%): 7,7
Minimum reported value: 0,85 µg
IRSST. "Détermination des amines dans l'air par LC-MS". Méthode 363. Méthodes analytiques. Montréal: IRSST, 2021.