IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

According to Decree 280-2024 published on February 28, 2024, in the Gazette officielle du Québec, the amendment to the Appendix 1 of the Regulation respecting occupational health and safety (RSST, RLRQ, c. S-2.1, r. 13) will come into force on March 14, 2024. These regulatory changes have not yet been incorporated into the current Substance Data Sheets of the Sampling Guide for Air Contaminants in the Workplace. An update is currently underway and will be available as soon as possible. Consequently, the information contained in the data sheets of substances modified or added in Decree 280-2024 is partially inaccurate or incomplete. Please consult our infoLABO (in French only) for more details. Please contact our client service: [email protected] for further information.

Titanium dioxide (Pt)  

French name in the regulation: Titane, dioxyde de (Pt)
CAS : 13463-67-7

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 10 - 1; Pt
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1C : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Titanium dioxide(Pt)

Analysis:

Weight measurement for total dusts

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
902 Preweighed PVC filter, 37 mm, 5 µm

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.

Weight measurement for total dusts

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
914 PVC filter, 25 mm, preweighed, 5 µm

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.

Weight measurement for total dusts

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
997 PVC filter, 37 mm 5 µm, preweighed, 3-part

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.